NFD-BRIDGE-IOLSA\W
Active

netFIELD IO-Link Wireless Bridge Class A

netFIELD IO-Link Wireless Bridge – integrates your sensors and actuators
  • Enables wireless technology for IO-Link Devices

  • Compatible with IO-Link standards of comparable performance

  • Firmware update over-the-air

  • Scan mode, simple pairing of IO-Link Devices

  • Wireless range of point-to-point communication up to 10 m

  • Robust IP67 design - No ingress of dust or water

Hilscher’s IO-Link technology platform netFIELD Device connects simple as well as complex sensors and actuators seamlessly in industrial Real-Time Ethernet networks.

The introduction of the innovative IO-Link Wireless communication significantly extends the scope of application of netFIELD Device. This opens machine builders and plant operators new possibilities to collect sensor data and monitor their plants.

The netFIELD Device IO-Link Wireless Class A Bridge is the counterpart of Hilscher’s IO-Link master and is directly connected to the respective sensors. The small coupling device for radio communication only needs a 24 V power connection to enable a fast and reliable wireless communication.

Hilscher’s netFIELD Devices need not be installed in control cabinets because they are IP67-rated and, thus, protected against the ingress of dust and water.

Category

Parameter

Value

Product

Part number

1912.103

Product name

NFD-BRIDGE-IOLSA\W

Description

IO-Link Wireless Class A Bridge, protected against dust and moisture.

Function

The bridge connects a wired IO-Link Device (Class A) via radio to an IO-Link Wireless Master and supplies it with power.

Power supply

Supply voltage

24 V DC, –25%/+30%
(18 V DC … 31.2 V DC) SELV/PELV or limited power supply (Class 2, according to IEC 61010-1-2010)

Voltages higher than 32 V can damage the device permanently.

Voltages below approx. 18 V may cause malfunction.

Output voltage

Corresponds to the supply voltage
(overcurrent protection at signal L+)

Power consumption (typical)

21 mA (at 24 V , without power consumption of the connected IO-Link Device)

Maximum input current (continuous)

1.021 A

Maximum output current (short-term peak current, max. 30 min)

1.221 A

Connector

M12, A-coded, plug

Reverse polarity protection

Not present

IO-Link connector

Communication

IO-Link Version 1.1

IO-Link

Class A

Transmission types

COM1, COM2, COM3

Maximum output current (permanent)

1.0 A

Maximum output current (short-term peak current, max. 30 min)

1.2 A

Connector

M12, A-coded, socket

IO-Link Wireless

Communication

IO-Link Version 1.1

Radio connection

1 Wireless point - IO-Link Wireless Device

Antenna

1, internal, isotropic

Frequency range

2.4 GHz

Maximum output power of the radio signal

10 dBm

Pairing

Push button

Bridge

Dimensions with M12 connectors (L x W x H)

66.6 mm x 35.6 mm x 35.6 mm

Dimensions without M12 connectors (L x W x H)

41.6 mm x 35.6 mm x 35.6 mm

Weight

Approx. 38 g (without optional bracket)

Protection class

IP67

Mounting

Mount (optional) or attach to the IO-Link Device

Installation location

In the radio range of the IO-Link Wireless Master and close to the connected IO-Link Device

The installation location must not be higher than 2000 m above sea level.

Displays

Power LED

Green

Status LED

RGB

Environmental conditions

Ambient temperature (operation)

–25 °C … +60 °C

Ambient temperature (storage)

–40 °C … +85 °C

Relative humidity

5% … 95%

CE

Standards

EN 301489

EN 300328

EN 62479

EN 61326:1

RoHS

Yes

Reach

Yes

Compliance

CE marking

Yes

UKCA marking

Yes

EMV Compliance

Emission EN 61000-6-4

EN 55016-2-3 (Radiated emission)

EN 55022 (Radio emission)

Immunity EN 61000-6-2

EN 61000-4-2:2009 (Electrostatic discharge immunity test)

EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated, radio-frequency, electromagnetic field immunity test)

EN 61000-4-4:2004 + A1:2010 (Electrical fast transient/burst immunity test)

EN 61000-4-5:2006 (Surge immunity test)

EN 61000-4-6:2009 (Immunity to conducted disturbances, induced by radio-frequency fields)

Shock and vibration resistance

Vibration resistance against sinusoidal vibrations

IEC 60068-2-6

Vibration resistance (random broadband noise)

IEC 60068-2-64

Shock resistance

IEC 60068-2-27

Product name

Part number

Brief description

NFD-BRIDGE-IOLSA\W

1912.103