NT 50-CO-RS Active mature

Gateway CANopen to Serial (ASCII) or Modbus RTU

Cost-optimized entry level gateway for simple conversions
  • Integrates a Modbus RTU device into a CANopen network, and vice versa

  • Integrates ASCII-protocol-supporting devices as nodes in CANopen

  • Space-saving, compact design

  • Loadable firmware for the flexible use of further conversions

  • With diagnosis and configuration interface via Ethernet

netTAP 50 connects to communication networks and acts as a Gateway for simple conversions between one Real-Time Ethernet protocol (1-port) and one fieldbus protocol or one serial automation protocol as well as between one fieldbus protocol and one serial automation protocol. netTAP 50 supports Slave-zu-Slave- and Slave-zu-Master-conversions. As a master, netTAP 50 provides only one single slave device with the full master function. This makes it easy to integrate a single field device into any higher-level network.

The design of the netTAP 50 convinces by its compact hardware and is reduced to the basic requirements of a protocol converter. The converter is directed to market segments for which the factor costs has priority. This makes the netTAP 50 an attractively priced and universally applicable gateway that offers a wide variety of conversion options.

Technical Data

Product

Product name

NT 50-CO-RS

Part number

1756.100

Brief description

Gateway CANopen to RS-232/422/485

Communication controller

Communication controller

netX 50

Integrated Memory

RAM

8 MB SDRAM

FLASH

4 MB serial Flash

Power supply

Supply voltage

24 V ± 6 V DC

Current consumption at 24 V (typically)

72 mA

Connector type

Mini-COMBICON, 2-pin

Communication interface X2

Communication interface

CANopen

Interface type

ISO 11898, optically isolated

Connector type

D-Sub male, 9-pin

Communication interface X3

Communication interface

Serial interface

Interface type

RS-232, RS-422, RS-485

Connector type

RJ45, Ethernet and serial interface together in one connector

Diagnostic interface

Type

Ethernet, 4-pin

Connector type

RJ45 socket

Display

LED displays

SYS System status

APL Application status

COM Communication status

LINK Link, ACT Activity

Permitted ambient conditions

Ambient temperature (operation)

0 °C … +60 °C

Ambient temperature (storage)

-40 °C … +85 °C

Relative humidity

10 % … 95 %, non-condensing

Altitude

0 m … 2000 m

Device

Dimensions (L x W x H)

100 x 26 x 66 mm (without connector)

Weight

appr. 80 g

Degree of protection

IP 20

Mounting type

on DIN rail EN 60715

Configuration

Configuration software

SYCON.net

Conformity

RoHS

Yes

Conformance with EMC directives

CE sign

Yes

Emission

EN 55011 / BS EN 55011

Immunity

EN 61131-2 / BS EN 61131-2

Order Information

Product name

Part number

Brief description

NT 50-CO-RS

1756.100

Gateway CANopen to Serial (ASCII) or Modbus RTU

Related products: Gateways & Switches for Industrial Ethernet/Fieldbus/Serial

NT 151-RE-RE

Data transmission between two Industrial Ethernet networks

NT 151-CCIES-RE/PNS

Data coupling between CC-Link IE Field and PROFINET

NT 50-CC-EN

Cost-optimized entry level gateway for simple conversions

NT 50-CC-RS

Cost-optimized entry level gateway for simple conversions

NT 50-CO-EN

Cost-optimized entry level gateway for simple conversions

NT 50-CO-RS

Cost-optimized entry level gateway for simple conversions

NT 50-RS-EN

Cost-optimized entry level gateway for simple conversions

NT 50-DN-EN

Cost-optimized entry level gateway for simple conversions

NT 50-DN-RS

Cost-optimized entry level gateway for simple conversions

NT 50-DP-EN

Cost-optimized entry level gateway for simple conversions

NT 50-DP-RS

Cost-optimized entry level gateway for simple conversions

NT 50-MPI

S7-SPS remote maintenance, programming, and visualization via Ethernet

NT 100-RE-CC

High-end gateway for demanding conversions

NT 100-RE-CO

High-end gateway for demanding conversions

NT 100-RE-DN

High-end gateway for demanding conversions

NT 100-RE-DP

High-end gateway for demanding conversions

NT 100-RE-EN

High-end gateway for demanding conversions

NT 100-RE-RS

High-end gateway for demanding conversions

NT 100-CO-CC

High-end gateway for demanding conversions

NT 100-CO-CO

High-end gateway for demanding conversions

NT 100-CO-DN

High-end gateway for demanding conversions

NT 100-CO-DP

High-end gateway for demanding conversions

NT 100-CO-RS

High-end gateway for demanding conversions

NT 100-DN-CC

High-end gateway for demanding conversions

NT 100-DN-CO

High-end gateway for demanding conversions

NT 100-DN-DN

High-end gateway for demanding conversions

NT 100-DN-DP

High-end gateway for demanding conversions

NT 100-DN-RS

High-end gateway for demanding conversions

NT 100-DP-CC

High-end gateway for demanding conversions

NT 100-DP-CO

High-end gateway for demanding conversions

NT 100-DP-DN

High-end gateway for demanding conversions

NT 100-DP-DP

High-end gateway for demanding conversions

NT 100-DP-RS

High-end gateway for demanding conversions

NL 50-MPI

S7-SPS remote maintenance, programming, and visualization via Ethernet

NL 51N-DPL

Upgrading a PROFIBUS Slave to PROFINET

Newsletter Form

Fieldset

Stay Up to Date

In our newsletter we inform you regularly about our latest products, solutions as well as participation in events such as exhibitions and conferences. In this way, we offer exciting insights into the world of Hilscher and automation technology. Sign up now!

Fieldset