Product | Part number | 1582.520 |
Brief description | Communication Module DeviceNet Slave |
Communication controller | netX | netX 52 |
Integrated Memory | FLASH | 4 MB serial Flash |
Power supply | Supply voltage | +3.3 V DC ± 5 % |
Typical/maximum current | 410 mA / 430 mA (at 3.3 V) |
Typical power consumption | approx. 1.35 W (at 3.3 V) |
Power connector | via system bus connector X1 |
System interface | Type | Parallel or serial dual-port memory interface |
Connector | 50-pin SMT connector, socket |
Pin distance | 1.27 mm |
Dual-port memory size | 16 KByte (lower 8 KByte used by firmware) |
Data width | 8/16 bit |
Serial dual-port memory interface | SPI Slave, mode 3 |
Baud rate | max. 50 MHz |
Communication interface | Communication standard | DeviceNet Slave |
Interface type | ISO-11898, according to DeviceNet specification, potential-free |
Connector | 30-pin SMT connector, socket, grid distance 1.27 mm, matching with plug type SAMTEC TFM-115-02-S-D–A |
Diagnostic interface | Type | UART or USB |
Connector | Signal at host interface. Available only if integrated in host system. |
Display | LED display | SYS System Status, green: RUN, yellow: RDY |
MNS Module network status, green: MS, red: NS |
Operating elements | Network address | 2 rotary switches for address |
Environment | Ambient temperature range for operation | -20 °C … +70 °C (Air flow during measurment: 0,5 m/s) |
Ambient temperature range for storage | -40 °C … +85 °C |
Humidity range | 10 % … 95 % relative humidity (non-condensing) |
Altitude | 0 … 2000 m |
Device | Dimensions (L x W x H) | 70 mm x 30 mm x 21.5 mm |
Weight | approx. 35 g ... 40 g |
Mounting | using screwable metal bolts, according to comX Design Guide |
Configuration | Configuration software | SYCON.net |
Conformity | RoHS | yes |
Conformance with EMC directives | CE sign | yes |
UKCA sign | yes |
Emission | EN 61000-6-4 / BS EN 61000-6-4 |
Immunity | EN 61000-6-2 / BS EN 61000-6-2 |
Electrostatic discharge (ESD) according to EN 61000-4-2 / BS EN 61000-4-2 (Air discharge method) | ± 8 kV, Criterion A |
Electrostatic discharge (ESD) according to EN 61000-4-2 / BS EN 61000-4-2 (Contact discharge method) | ± 6 kV, Criterion A |
Fast transient interferences (Burst) according to EN 61000-4-4 / BS EN 61000-4-4 | ± 2 kV, Criterion A (Communication lines, shielded) |
Surge voltage according to EN 61000-4-5 / BS EN 61000-4-5 (Communication and data lines) | 1 kV, Criterion A (Communication lines, shielded) |