General | Part number | 9233.923 |
Dimensions (W x H x D) | 35 x 90 x 127 mm |
Weight | 160 g |
Mounting | Top hat rail 35 mm (IEC/EN 60715) |
Mounting position | Vertical |
Standards | IEC/EN 61131-2 |
Communication controller | netX 50 processor |
Configuration and diagnostic interface | Mini-USB |
Integrated memory | 8 MB SDRAM 4 MB serial Flash EPROM |
Ambient mechanical conditions | Protection type (IEC/EN 60529, EN50178, VBG 4) | IP20 |
Vibrations (IEC/EN 61131-2:2008) | Constant amplitude 3.5 mm: 5 – 9 Hz Constant acceleration 1 g: 9 – 150 Hz |
Mechanical shock resistance (IEC/EN 60068-2-27) | Semi-sinusoidal 15 g/11 ms: 9 Shocks |
Drop to (IEC/EN 60068-2-31) | Drop height: 50 mm |
Free fall, packaged (IEC/EN 60068-2-32) | Drop height: 1 m |
Ambient climatic conditions | Operating ambient temperature (IEC 60068-2) | -25…+55 °C |
Condensation | Prevent by suitable measures |
Storage | -40…+70 °C |
Relative humidity, non-condensing (IEC/EN 60068-2-30) | 5…95 % |
Electromagnetic compatibility (EMC) | Pollution degree | 2 |
Electrostatic discharge (IEC/EN 61131-2:2008) | Air discharge (Level 3): 8 kV Contact discharge (Level 2): 4 kV |
Electromagnetic fields (IEC/EN 61131-2:2008) | 80 – 1000 MHz: 10 V/m 1.4 – 2 GHz: 3 V/m 2 – 2.7 GHz: 1 V/m |
Radio interference suppression (SmartWire-DT) | EN 55011 Class A |
Burst (IEC/EN 61131-2:2008, Level 3) | Supply cables: 2 kV Sercos bus cable: 1 kV SmartWire-DT cables: 1 kV |
Surge (IEC/EN 61131-2:2008, Level 1) | Supply cables: 0.5 kV Sercos bus cable: 1 kV |
Radiated RFI (IEC/EN 61131-2:2008, Level 3) | 0,15 – 80 MHz, 10 V, 80% AM / 1 KHz |
Supply voltage UAUX | Rated operational voltage | 24 V DC -15 % +20 % |
Input voltage residual ripple | ≤ 5 % |
Protection against polarity reversal | Yes |
max. current Imax | 3 A Note: If contactors with a total power consumption > 3 A are connected, a power feeder module EU5C-SWD-PF1/2 has to be used. |
Short-circuit strength | No, external fuse FAZ Z3 |
Heat dissipation | Typ. 1 W |
Potential isolation | No |
Rated operating voltage of 24-V-DC slaves | Typ. UAUX -0,2 V |
Supply voltage UPOW | Supply voltage | 24 V DC -15 % +20 % |
Protection against polarity reversal | ≤ 5 % |
Protection against polarity reversal | Yes |
Rated operational current I | 111 mA (with two participants) |
Heat dissipation at 24 V DC | 2.66 W (with two participants) |
Potential isolation between UPOW and 15-V-SmartWire-DT supply voltage | No |
Bridging voltage dips | 10 ms |
Repeat rate | 1 s |
Status display | POW LED |
SmartWire-DT supply voltage | Rated operational voltage Ue | 15 V ± 3 % |
max. current Imax | 0.7 A Note: If contactors with a total power consumption > 0.7 A are connected, a power feeder module EU5C-SWD-PF2 has to be used. |
Short-circuit strength | Yes |
Connection supply voltages | Connection type | Push-in terminals |
solid | 0,2 – 1,5 mm2 (AWG 24 – 16) |
Flexible with ferrule | 0,25 – 1,5 mm2 |
SmartWire-DT network | Participant type | SmartWire-DT master |
SmartWire-DT Master ASIC | SWD-80P-RS485 |
Number of SmartWire-DT slaves | 99 |
Baud rate | 125 / 250 kBd |
Address setting | Automatic |
Status display | SmartWire-DT master: SWD LED, duo color red/green Configuration: Config LED, duo color red/green |
Connections | Plug, 8-pole |
Plug connectors | Blade terminal SWD4-8MF2 |
Ethernet Sercos network | Function of gateway | Sercos Slave |
Baud rate | 100 MBit/s |
Interface type | 100 BASE-TX |
Auto-Negotiation | Supported |
Auto-Crossover | Supported |
Address setting | By project configuration |
Status display | Sercos LED: S, duo color red/green (orange) |
Connector socket | 2 x RJ45 |
Connector plug | RJ45 |
Potential isolation | Yes |