COMX 52CN-DPS
Serie

Kommunikationsmodul SPI - PROFIBUS DP-Slave

Das Modul für alle Kommunikationsaufgaben
  • Universelle PROFIBUS DP-Slave-Schnittstelle mit Netzwerkanschluss zur Hauptplatine

  • Erlaubt die flexible Positionierung des Netzwerksteckers

  • Host-Anbindung über Dual-Port-Memory oder SPI

  • Funktionskompatibler Ersatz für comX 10CN-DPS

The module for all communication tasks

The comX communication module is designed to be integrated into automation devices to provide drives, robot controllers, PLCs, etc. with a network interface. Communication tasks are all executed autonomously in the module - irrespective of the processor of the target device.

Process data is exchanged via a Dual-Port-Memory per access by an 8-/16-bit bus interface or a fast 50 MHz SPI interface.

comX supports all leading Real-Time Ethernet protocols as Master or Slave and meets all network-specific requirements in just one single module. To support a line topology, the module is equipped with two Ethernet ports. The communication protocol can be changed simply and reliably by loading the appropriate firmware and a software license for masters.

Due to the Hilscher network controller netX, a 10-year delivery guarantee is granted.

COMX 52CN-DPS

Parameter

Value

Product

Part number

1582.420

Description

Communication module PROFIBUS DP Slave

Communication controller

netX

netX 52

Integrated memory

Flash

4 MB SPI Flash EPROM

Voltage/power supply

Supply voltage

+3.3V DC ± 5%

Typical/maximum current consumption

400 mA / 440 mA (at 3.3 V)

In case of a short circuit of the 5 V PROFIBUS supply, the current consumption increases by further approx. 70 mA.

Typical power consumption

Approx. 1.35 W (at 3.3 V)

Connector

Via system bus interface X1

System interface

Type

Parallel or serial dual-port memory interface

Connector

50-pin SMT connector, socket

Pin distance

1.27 mm

Dual-port memory size

16 KB (lower 8 KB used by firmware)

Data width

8/16 bit, switchable

Serial dual-port memory interface

SPI slave, mode 3

Baud rate

max. 50 MHz

Communication interface

Communication standard

PROFIBUS DP Slave

Interface type

RS-485, isolated

Connector

30-pin SMT connector, socket, 1.27 mm pitch, suitable for connector type SAMTEC TFM-115-02-S-D–A

Transmission rate

9.6 kBits/s, 19.2 kBits/s, 31.25 kBits/s, 45.45 kBits/s,93.75 kBits/s, 187.5 kBits/s, 500 kBits/s,1.5 MBits/s, 3 MBits/s, 6 MBits/s, 12 MBit/s

Auto detection

Yes

Diagnostic interface

Type

UART or USB

Connector

Signal on the host interface. Available only if integrated with host system.

Display

LED display

SYS system status, green: RUN, yellow: RDY

COM communication status, green: RUN, red: ERR

Operating elements

Network address

2 rotary switches for address

Environment

Operating temperature range

-20 °C … +70 °C (Air flow during measurment: 0.5 m/s)

Temperature range for storage

–40 °C … +85 °C

Humidity range

10 % ... 95 % relative humidity (non-condensing)

Device

Dimensions (L x W x H)

70 mm x 30 mm x 21.5 mm

Weight

approx. 35 g ... 40 g

Mounting

Using screwable metal bolts, according to comX Design Guide

Configuration

Configuration software

SYCON.net

Compliance

RoHS

Yes

Compliance with EMC guidelines

CE marking

Yes

UKCA marking

Yes

Emission

EN 61000-6-4

Immunity

EN 61000-6-2

Electrostatic discharge (ESD) according to EN 61000-4-2:2009-12 (Contact discharge method)

± 6 kV, criterion A

Fast transient interferences (burst) according to EN 61000-4-4:2013-04

± 2 kV, criterion A (communication lines, shielded)

Surge voltages according to EN 61000-4-5:2019-03

1 kV, criterion A (communication lines, shielded)

Product name

Part number

Brief description

COMX 52CN-DPS

1582.420/DPS

Communication module SPI - PROFIBUS DP Slave

Accessory
COMXEB

comX Evaluationboard