COMX 100CN-CO
Communication module dual-port memory - CANopen

Flexible communication module for automation
  • Universal CANopen interface (Master or Slave) with network connection to the mainboard

  • Allows a flexible positioning of the network connector

  • Master or slave on the same hardware

  • Usable immediately due to preloaded firmware

  • Host connection via dual-port memory

The module for all communication tasks

The comX communication module is designed to be integrated into automation devices to provide drives, robot controllers, PLCs, etc. with a network interface. Communication tasks are all executed autonomously in the module - irrespective of the processor of the target device.

Process data is exchanged via a Dual-Port-Memory per access by an 8-/16-bit bus interface or a fast 50 MHz SPI interface.

comX supports all leading Real-Time Ethernet protocols as Master or Slave and meets all network-specific requirements in just one single module. To support a line topology, the module is equipped with two Ethernet ports. The communication protocol can be changed simply and reliably by loading the appropriate firmware and a software license for masters.

Due to the Hilscher network controller netX, a 10-year delivery guarantee is granted.

COMX 100CN-CO

Parameter

Value

Product

Part number

1532.500

Brief description

Communication Module CANopen

Communication controller

netX

netX 100

Integrated Memory

RAM

8 MB SDRAM

FLASH

4 MB serial Flash

Power supply

Supply voltage

+3.3 V DC ± 5 %

Typical/maximum current

approx. 450 mA … 480 mA (at 3.3 V)

Typical power consumption

approx. 1.5 … 1.6 W

Power connector

via system bus connector X1

System interface

Type

Parallel Dual-port memory interface

Connector

50-pin SMT connector, socket

Pin distance

1.27 mm

Dual-port memory size

16 KByte

Data width

8/16 bit

Communication interface

Communication standard

CANopen

Interface type

ISO-11898, potential-free

Connector

30-pin SMT connector, socket, grid distance 1.27 mm, matching with plug type SAMTEC TFM-115-02-S-D–A

Diagnostic interface

Type

UART or USB

Connector

Signal at host interface. Available only if integrated in host system.

Display

LED display

Signals at X2 for SYS System Status, green: RUN, yellow: RDY

Signals at X2 CAN Communication status, green: STA, red: ERR

Environment

Ambient temperature range for operation

-20 °C … +65 °C (Air flow during measurment: 0,5 m/s)

Ambient temperature range for storage

-40 °C … +85 °C

Humidity range

10 % … 95 % relative humidity (non-condensing)

Device

Dimensions (L x W x H)

70 mm x 30 mm x 21.5 mm

Weight

approx. 35 g ... 40 g

Mounting

using screwable metal bolts, according to comX Design Guide

Configuration

Configuration software

SYCON.net

Conformity

RoHS

yes

Conformance with EMC directives

CE sign

yes

UKCA sign

yes

Emission

EN 61000-6-4 / BS EN 61000-6-4

Immunity

EN 61000-6-2 / BS EN 61000-6-2

Electrostatic discharge (ESD) according to EN 61000-4-2 / BS EN 61000-4-2 (Air discharge method)

EN 61000-4-2 / BS EN 61000-4-2: ± 10 kV, Criterion B

Electrostatic discharge (ESD) according to EN 61000-4-2 / BS EN 61000-4-2 (Contact discharge method)

EN 61000-4-2 / BS EN 61000-4-2: ± 6 kV, Criterion B

Fast transient interferences (Burst) according to EN 61000-4-4 / BS EN 61000-4-4

EN 61000-4-4 / BS EN 61000-4-4: ± 2 kV, Criterion A (Communication lines, shielded)

Surge voltage according to EN 61000-4-5 / BS EN 61000-4-5 (Communication and data lines)

EN 61000-4-5 / BS EN 61000-4-5: 1 kV, Criterion A (Communication lines, shielded)

Product name

Part number

Brief description

COMX 100CN-CO

1532.500/COM

Communication module dual-port memory - CANopen

Accessory

comX Evaluation Board

Development platform for all comX types