NFS-M8-QM-D2-N16

NFS-M8-QM-D2-N16

Announced

At a glance

  • Instant solution for monitoring up to 8 IO-Link sensors
  • Data transmission to the cloud at minimum rate of a second
  • Automatic IO-Link configuration via Internet IODD file database
  • Central device management and data visualization via Internet portal
  • Cloud API for realtime data streaming into any remote application

Weitere Informationen

Description

Instant-IO-Link Solution for Remote Monitoring your Sensor Data

sensorEDGE is Hilscher’s solution for fast remote monitoring your machines. Equipped with two netIOL chips – an IO-Link master controller developed by Hilscher – as well as a cloud uplink, the sensor box enables data monitoring and analyzing of up to eight IO-Link sensors simultaneously.

sensorEDGE simply needs a power supply and an internet connection. A complex setup of a PLC or fieldbus system is not required.

As soon as sensors are plugged in and are autonomously configured via the online IODD file database, the sensor-box transmits data into the cloud at a rate of a second. The data can either be visualized immediately in the corresponding cloud web frontend or streamed into any third-party application utilizing the integrated API.

sensorEDGE is the ideal solution for retrofitting existing plants which had been managed and operated locally but have never been remotely monitored. The sensor-box is compatible with all IO-Link-sensors that operate in accordance with the IEC 61131-9 protocol standard, simplifying the implementation of sensorEDGE enormously. The IP67-rated casing is able to withstand harshest environments and allows for a cabinet-free installation close to your machines.

Technical Details

Technical data sensorEDGE

CategoryParameterValue
GeneralPart number1915.230
Functions8-port IO-Link Master (Class A) Edge Device with sensorEDGE Cloud connectivity
Power supplySupply voltage+24 V DC, –25%/+30% (18 V DC … 31.2 V DC)
Note: Voltages above 34 V may cause permanent damage to the device.
Voltages below approx. 10 V will cause a shutdown of the device.
Note: The sensorEDGE does not need or use auxiliary supply voltage (U2L), even though the pins for the 2L auxiliary load circuit are implemented on the device. The 1L and 2L load circuits are galvanically isolated from each other.
Under-voltage warningU1L < 18 V: 1L LED shows steady red
U1L > 17.7 V: 1L LED returns to steady green
Over-voltage warningU1L > 30 V: 1L LED blinking red (4 Hz)
U1L < 29.7 V: 1L LED returns to steady green
Current consumption (typical)150 – 160 mA (at 24 V DC)
Maximum current at supply connector16 A with airflow of ~ 0.5 m/s.
3.36 A without airflow
Note: Always protect the power supply with a circuit breaker or fuse. For this purpose, use a 24 V DC / max. 16 A fuse or circuit breaker with type B trip characteristics.
Reverse voltage protectionYes
Mains buffering
(power failure bridging)
10 ms (at 24 V)
ConnectorM12 L-coded, male, 5-pin (4 + FE)
Recommended tightening torque of locking nut: 0.4 – 0.6 Nm
Mechanics and housingDimension (L x W x H)200 mm x 60 mm x 30 mm
Weight420 g
Housing materialGlass fiber reinforced plastic (PBT) according to UL 94-V0
Housing colorRAL 7035 (“light gray”)
Degree of protectionIP67 (EN 60529)
Protection classIII (EN 61140)
Mounting typeTo be attached to carrier with two M4 screws.
Recommended tightening torque: 0.8 Nm
Admissible ambient conditionsAmbient temperature for operation–25 °C … +60 °C at maximum current consumption per IO-Link port of 400 mA without airflow.
–25 °C … +60 °C at maximum current consumption per IO-Link port of 1800 mA with airflow of ~ 0.5 m/s.
Ambient temperature for storage–40 °C … +85 °C
Max. temperature change3 K / min
Relative humidity (operation)5 % … 95 %
Pollution degree3 (EN 60664-1)
Altitude0 ... 2000 m
Overvoltage categoryII (EN 60664-1)
Electromagnetic compatibility (EMC)Radio Interference Field Strength EmissionDIN EN 55016-2-3 / BS EN 55016-2-3
Radiated Field ImmunityDIN EN 61000-4-3 / BS EN 61000-4-3
Conducted Disturbances ImmunityDIN EN 61000-4-6 / BS EN 61000-4-6
Radio Interference Voltage EmissionDIN EN 55016-2-1 / BS EN 55016-2-1
ESD contact dischargeDIN EN 61000-4-2 / BS EN 61000-4-2
4 kV
BurstDIN EN 61000-4-4 / BS EN 61000-4-4
SurgeDIN EN 61000-4-5 / BS EN 61000-4-5
Mechanical testsVibration sinusoidalDIN EN 60068-2-6:2008 (including monitoring for contact breaks according to DIN EN 60512-2-5:2004)
ShockDIN EN 60068-2-27:2010 (including monitoring for contact breaks according to DIN EN 60512-2-5:2004)
Free fallDIN EN 60068-2-31:2009
ApprovalsULIn preparation
Conformity declarationsCEYes
UKCAYes
RoHSYes
REACHYes
Ethernet LAN interfaceType10/100 MBit/s Ethernet port (eth0)
ConnectorM12, D-coded, female, 4-pin.
Recommended tightening torque of locking screw: 0.4 – 0.6 Nm
IO-LinkTypeIO-Link Master, Class A, 8 ports
Connector8 x M12 A-coded, female, 5-pole
Recommended tightening torque of locking screw: 0.4 – 0.6 Nm
Maximum cable length: 20 m.
LED indicatorsSYS (green/yellow)“System” status LED of the communication controller
Wi-Fi/Bluetooth (blue)Currently without function (reserved for future use)
EDG (red/green)“Edge” LED indicating configuration and operating states of the IO-Link sensors
CLD (red/green)“Cloud” LED indicating connectivity with the Internet/cloud
RUN (red/green)Currently without function (reserved for future use)
ERR (red/green)Currently without function (reserved for future use)
LINK (green)Ethernet Link status
ACT (yellow)Ethernet Activity status
1L (red/green)Indicates supply voltage status
2L (green)Indicates supply voltage status of second load circuit (U2L).
Note: The sensorEDGE does not need or use auxiliary supply voltage (U2L), even though the 2L LED and the pins for the 2L auxiliary load circuit are implemented on the device.
8 x A (red/green/yellow)Status of the IO-Link port
(Note: Yellow is produced by switching red and green duo LED on at the same time)
8 x B (red/green/yellow)Not used

Technical data IO-Link ports

CategoryParameterValue
IO-Link Master (Class A)SpecificationV1.1.2
Port modeIO-Link autoconfig
Min. cycle time400 µs
Sensor supplyOutput voltage24 V DC, 1L-powered
CurrentMaximum current consumption per IO-Link port without airflow: 400 mA.
Maximum current consumption per IO-Link port with airflow of ~ 0.5 m/s: 1800 mA.
CircuitHigh-side driver, no back current protection from 1L+ output.

Ordering information

Product namePart numberBrief description
NFS-M8-QM-D2-N161915.230sensorEDGE - Cloud based instant IO-Link data provisioning solution

Downloads

Documentation

Software

The sensorEDGE Portal provides functions to update the software of the sensorEDGE device.

 

Brochures, Whitepaper and Case Studies

Find all our current Media to Industry 4.0 / Industrial Internet at our Media Archive.