Technologies

  • Industrial Ethernet
  • PROFINET
  • Ethernet TCP
  •  

Ethernet LAN PROFINET IO-Controller

LAN controlled PROFINET IO-Controller for DIN rail

Product Image

 

NHST-T100-EN-Image

NHST-T100-EN/PNM

Active

At a glance

  • Fully featured PROFINET IO-Controller for up to 128 PROFINET Slaves
  • Open access via TCP/IP-based access protocol
  • Quick access via DLL with same API as PC fieldbus cards
  • Easy integration in embedded systems via 'C'-based driver source code
  • Supports RTC, RTA, DCP, CL-RPC, Alarm protocol

Weitere Informationen

Description

A netHOST RTE is a full-featured and autonomously operating Real-Time Ethernet master allowing industrial PCs and other embedded systems the control of Real-Time Ethernet networks over an ordinary LAN connection.

A simple TCP/IP based transport protocol transfers the services between the controlling unit and the device. For device integration a DLL for Windows and a ‚C‘ source code for embedded solutions is provided. In both cases the call interface (API) is identical to Hilschers PC cards. This makes a netHOST a „remotely controllable PC card forield installations“.

100 bytes process data inputs and outputs are exchangeable over the LAN network in about one millisecond.

Acyclic services to the subordinate Real-Time Ethernet stations are supported as well. A bus configuration software is included in the delivery. Two devices can be used in combination to realize redundant applications. Services are provided to execute a controlled switchover in the event one device fails or a line breaks. In case a device fails the memory card slot allowservice personnel to perform a firmware and configuration recovery on a replacement device in less than a minute.

Technical Details

ProductProduct nameNHST-T100-EN/PNM
Part number1890.840
Brief descriptionEthernet LAN PROFINET IO-Controller
Communication controllernetXnetX 100
Integrated MemoryRAM8 MB SDRAM
FLASH4 MB serial Flash
Memory cardType and sizeSD card, max. 2 GByte. SDHC- or SDXC-card type must not be used.
Power supplySupply voltage24 V DC ± 6 V
Maximum Current at 24 V (typically)130 mA
Typical power consumption3,2 W
ConnectorMini-COMBICON, 2-pin
Reverse voltage protectionyes
Requirement to the power supplyFor UL conform usage: Device shall be supplied by an isolated voltage source
Communication interface 1Communication standardEthernet
Interface type100BASE-TX or 10BASE-T, isolated
Connector2 * RJ45
Communication interface 2Communication standardEthernet
Interface type100BASE-TX or 10BASE-T, isolated
Connector1 * RJ45
Diagnostic interfaceTypeUSB
ConnectorMini-USB, 5-pin
DisplaysLED displaysSYS System status netHOST
APL Application status netHOST
SF Communication status
BF Communication status
LINK Link
ACT Activity
EnvironmentAmbient temperature range for operation0 … +60 °C
Humidity rangeno condensation permitted
Pollution degreeFor UL-compliant usage: Device must be used in a pollution degree 2 environment
DeviceDimensions (L x W x H)100 x 52 x 70 mm (without connector)
Weightappr. 150 g
Degree of protectionIP 20
Mountingon DIN rail EN 60715
ConfigurationConfiguration softwareSYCON.net
Ethernet Device Configuration Tool
ConformityRoHSYes
Conformance with EMC directivesCE signYes
EmissionCISPR 11 Class A
ImmunityEN 61131-2:2003

Ordering information

Product name Part number Brief description
NHST-T100-EN/PNM1890.840Ethernet LAN PROFINET IO-Controller