A/B slaves |
permit the extension of the address space to 62 Slave in an AS interface leg
|
|
Adapter |
is a passive device in a ControlNet with respect to cyclic data traffic.
It cannot independently take up a cyclic connection to another node but acyclic connections are always possible.
|
|
Analog module |
for transmission of up to 24 Bit analog values utilizing a sequential data transfer
|
|
AS-i power supply |
for supplying the whole system with
power with concurrent decoupling
of the data
|
|
AT |
Drive telegram, each Slave sends its AT in the corre sponding time slot
|
|
Bit strobe |
Multi/Broadcast I/O data exchange
|
|
Bootup |
Starting sequence of the node
|
|
CIP |
(Control and Information Protocol) describes the means of addressing in order to create a connection to a communication Object of a ControlNet node.
|
|
Consumer |
Device that receives data
|
|
Consumer/ Producer |
describes the process for characterizing and addressing data within a ControlNet system.
|
|
COS |
change of state
Transfer of data when data has changed
|
|
CP0-CP4 |
Communication phase
|
|
Cyclic |
timer controlled data transfer
|
|
DP |
Decentral Periphery
|
|
DPM1 |
Master class 1 controls the cyclic data exchange
|
|
DPM2 |
Master class 2 diagnostic, configuration and monitor
|
|
DPV1 |
DP extension, acyclic services
|
|
EMCY |
Emergency, Emergency notification
|
|
Explicit messaging |
acyclic data channel
|
|
FDL |
Fieldbus Data Link defines the PROFIBUS communication on layer 2, identical for DP and FMS
|
|
FMS |
Fieldbus Message Specification
|
|
Generation 4 |
latest InterBus technology generation
|
|
GSD |
Device description file
|
|
Guarding |
Monitoring the node
|
|
Hub |
Central connection device for star-formed cabling
|
|
ID-Code |
classification code of a device
|
|
IDN |
Identification number
|
|
Length code |
coded I/O length information of a device
|
|
Local bus |
local branch from main cable
|
|
Loop |
InterBus transfer technique for the area of simple sensors/actuators
|
|
Master |
active device, controls the bus access
|
|
MDT |
Master Datentelegramm, Data to the Slaves, Broadcast
|
|
Media-Redundancy |
of the network is an option of the system in order to reduce shut downs of the whole network.
|
|
Monomaster |
one Master in the network
|
|
MST |
Master synchronisation telegram, allows the synchronisation of all connected Slaves via a AT
|
|
Multimaster |
multiple Master in the network
|
|
NMT |
Network management
|
|
PA |
Process Automation
|
|
Parameter data |
for acyclic control of AS-Interface Slaves, e.g. shutting the sending diode of a light barrier on or off
|
|
PCP |
Peripherals Communication Protocol acyclic data channel
|
|
PDO |
Process Data Object, Process data channel
|
|
PDO mapping |
Configuration of process data per PDO
|
|
Polling |
acyclic I/O data exchange
|
|
Predefined Master/Slave |
predefined connection set up between Master and Slave
|
|
Producer |
Device that sends data
|
|
Remote bus |
RS422 or fibre-optics conductor main cable
|
|
SAP |
Service Access Point
|
|
Scanner |
is required for establishing cyclic data traffic between ControlNet-participants.
It is therefore responsible for the organization of the NUI (Network Update Interval).
|
|
Scheduled Data Exchange |
is planned cyclic data exchange for transmission of input/output data.
|
|
SDO |
Service Data Object, acyclic data channel
|
|
SERCOS |
Serial Realtime Communication System
|
|
Slave |
passive device, answers to the master
|
|
Switch |
Central intelligent connection device for star-formed cabling and solution of access conflicts
|
|
SYNC |
Sychronisation cycle of the master
|
|
TCP/IP |
Transport Control Protocol/Internet Protocol connection-orientated, secure transfer protocol as basis for the Internet-protocols
|
|
UCMM |
Unconnected Message Manager
|
|
UDP |
User Datagram Protocol connectionless, unsecured data transfer protocol for Broadcast and Multicast communication
|
|
Unscheduled Data Exchange |
is unplanned acyclic data exchange for transmission of configuration or parameter data.
|